    Default FAS Systems?

    Anyone remember a link that was on the rant on the left side that was for a company named FAS? Either like Firehouse Alerting System, or Firefighter Alerting System....something like that. They made devices that you plug into your Minitor III-V charger's AUX port...

    The link is gone, wondering if this company went out of business?
    Don't F*ck with Truck

    The opinions stated above are mine and only mine and in no way are they the opinions of my department, village, town, blah, blah, blah....you know the drill

  2. #2
    Chief of Special Hops CollegeFire
    Join Date
    Feb 2008
    Location
    Oyster Bay
    Posts
    557

    Default Re: FAS Systems?


  3. #3
    1612 MFDTruck2
    Join Date
    Nov 2005
    Location
    160
    Age
    29
    Posts
    321

    Default Re: FAS Systems?

    Not cheap is right! I just got a Minitor IV and noticed the acessory port on the back and rememberd that someone made like a strobe or something that hooked up to it and it seemed like a great idea for those ngiht fires, but it's a little too pricey for my tastes.
    Don't F*ck with Truck

    The opinions stated above are mine and only mine and in no way are they the opinions of my department, village, town, blah, blah, blah....you know the drill

  4. #4

    Join Date
    Nov 2006
    Posts
    410

    Default Re: FAS Systems?

    Also, you can probably make one on your own for rather cheap, with some wiring experience. From Minitor I/II/III/IV

    Remote Speaker Audio (Pins 1 & 6)
    An external four-ohm speaker may be connected
    to the charger/amplifier via pin 1 (audio) and
    pin 6 (ground return) of the plug, to provide both
    remote speaker audio and internal speaker audio
    at the same time.
    Relay Dry Contact Closure (Pins 2 & 3)

    When the accessory relay is energized, its contacts
    close and present a short across pins 2 and 3 of the
    connector. The relay contacts are rated for 10 watts,
    maximum at 28 volts dc/ac rms. Within the limits of
    the 10 watt rating, the closed contacts will handle up
    to 750 milliamperes continuously and will switch up to
    400 milliamperes of current.
    Relay Closure Timing Control (Pins 4 & 5)
    Pins 4 and 5 of the accessory connector are used to
    select the time duration of the relay contact closure.
    If these two pins are NOT used (open circuit), the relay
    will remain energized for approximately 10 seconds after
    an alert is received. If pins 4 & 5 are SHORTED, the relay
    will remain energized until the 'RESET' button on the front
    of the charger/amplifier is depressed. Pressing the
    'RESET' button causes the contacts to open and turns off
    the ALERT indicator."

Similar Threads

  1. Bail Out Systems
    By zeroone in forum Firefighter Survival
    Replies: 144
    Last Post: 09-14-2010, 10:14 AM
  2. Trunked Systems
    By metallicamaster3 in forum The Radio Room
    Replies: 2
    Last Post: 05-04-2008, 11:56 PM
  3. bailout systems
    By ranter in forum Firefighter Survival
    Replies: 4
    Last Post: 02-01-2008, 04:05 PM
  4. Dispatch Systems
    By LtDan in forum The Radio Room
    Replies: 45
    Last Post: 09-12-2007, 07:06 PM
  5. Nassau Police new systems
    By tiller3 in forum The Radio Room
    Replies: 11
    Last Post: 01-01-2007, 04:52 PM

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •